All pharamacopoeial monographs in one site

Image
From this site you can search any pharamacopoeial monograph ๐Ÿ‘‡                  https://youtu.be/E7gXjs6iStA

C8 vs C18 HPLC columns

Image
 1- C8 : Has only 8 carbon atoms chain bonded to silica atom, less dense than C18 (Decreases the surface area) so the elution will be faster (Decreases retention time). 2- C18 : Has only 18 carbon atoms chain bonded to silica atom, more dense than C8 (Increases the surface area) so the elution will be slower (Increases retention time).

Analysis of paracetamol, caffeine and their impurities

Image
 

HPLC & Human body

Image
Learn HPLC in a new style !!  In this book you will see a big similarity between HPLC and Human body ๐Ÿ™„๐Ÿค” For Pay Pal users pay only 2$

Thermo scientific application for HPLC troubleshooting

Image
 

Try to solve these problems ๐Ÿค”

Image
 

How to solve HPLC troubleshooting

Image
 

USP equivalent GC columns

Image
 

Ethinylestradiol assay according to the Chinese Pharmacopoeia

Image
  1- Mobile phase preparation : - Eluent (A) : Methanol - Eluent (B) : Water - Eluent (A) : Eluent (B)             70   :   30 2- Column :   Acclaim 120 C18 ( 25 cm x 4.6 mm x 5  ยตm ) 3- Column oven temp. :   25   °C 4- Detector :   UV 220nm 5- Injection volume :  1 0 ยตL 6 - Chromatogram : Peak 2 : Ethinylestradiol

Search any HPLC method of analysis in this site

Image
  https://appslab.thermofisher.com/App/3543/assay-analysis-sodium-lactate

How to install a guard column

Image
 

Factors affect on retention time of peak

Image
 

Determination of melamine in Liquid & Powder milk by HPLC

Image
1- Mobile phase preparation : - Eluent (A) :10 mM  Acetic acid + 10 mM Ammonium acetate, pH 4.3 (70:30 v/v) - Eluent (B) : A cetonitrile - Eluent (A) : Eluent (B)             80   :   20 2- Column :   Acclaim Mixed-Mode WCX-1 ( 25 cm x 4.6 mm x 5  ยตm ) 3- Column oven temp. :   30 °C 4- Detector :   UV 240nm 5- Injection volume :   20 ยตL 6 - Chromatogram : - Peak 1 : Melamine

Reversed phase vs Normal phase

Image
 

For all HPLC operators, avoid these things ๐Ÿ˜ฑ

Image
 

Gas chromatography "Direct injection vs Headspace injection"

Image
 

How to back flush HPLC column

Image
 

Theory of operating HPLC column in reversed flow direction

Image
Many operators try to reverse the flow direction of HPLC column to obtain acceptable system suitability results such as ( Tailing factor, Plate count and resolution ) - In your opinion, Do you think that this actually affects on system suitability ? - What is the scientific theory of this ? - Do you think that this will affect on the column performance on the long run ๐Ÿค”?  " Lets discuss this with each other in the comments ๐Ÿ‘‡"

Quantitation of Ethanol in pharmaceutical products using GC

Image
 

Flexibility of HPLC parameters adjustment

Image
 

Separation of arginine and glutamic acid without derivatization using HPLC-UV

Image
  1- Mobile phase preparation : - Eluent (A) :  potassium dihydrogen phosphate, 25 mM, pH 2.85 - Eluent (B) : A cetonitrile - Eluent (A) : Eluent (B)             25   :   75 2- Column :   Acclaim Mixed-Mode HILIC-1 ( 25 cm x 4.6 mm x 5  ยตm ) 3- Column oven temp. :   30 °C 4- Detector :   UV 200nm 5- Injection volume :   20 ยตL 6 - Chromatogram : - Peak 1 : Glutamic acid - Peak 2 : Arginine - Peak 3 : Impurity